Hangzhou Color Powder coating Equipment co.,ltd
|
Payment Terms: | T/T,WU |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Electrical data | |
Mains input voltage | 100-240 VAC |
Operating frequency | 50-60 Hz |
Input power | 50W |
Nominal output voltage (to the gun) | max. 12 V |
Nominal output current (to the gun) | max. 1 A |
IP54 | |
Ambient temperature range | 0°C - +40°C (+32°F - +104°F) |
Max. operating temperature | 85°C (+185°F) |
Approvals | CE |
Pneumatical data | |
Compressed air connection | 1/4" male quick release |
Max. input pressure | 10 bar / 145 psi |
Min. input pressure (while unit in operation) | 6 bar / 87 psi |
Max. water vapor content of the compressed | air 1.3 g/m³ |
Max. oil vapor content of the compressed air | 0.1 mg/m³ |
Problem | Cause | Measure |
High –voltage display does not operated even after powder is on and trigger is pulled | . Electric faulty-The electric line coming into CONTROL UNIT is not property connected . Faulty fuse and bad equipemnt on the part of external power source . .Faulty lamp. .Faulty printed circuit board(PCB) .Faulty line in GUN .Faulty in high-voltage generation part .Faulty trigger switch | . connect the power Replace Preplace Preplace Preplace Preplace Preplace Preplace |
The powder would not be fluidized | .The fluidzing air hose is not connected or compressed air is not input . Faulty fluidizing plate . Faulty operation of pressure reduction valve | .Connect after checking .Replace .Replace |
The gauge hands of CONVERYING AIR and DOSING AIR do not move during operation | .operation mistake: The power switch is not pressed .The trigger is not pulled .Faulty SOLENOID valve .Faulty PCB | . Turn on the power switch .Check while pulling the trigger . Replace |
Problem | Cause | Measure |
The powder would not be ejected even after power switch is on and trigger is pulled | .Blolckage generated in injector , check valve sleeve in the injector paint hose or GUN . worn-down sleeve .Poor fluildfying operation .CONVERYING AIR is not supplied. . Faulty air –adjustment valve . Faulty solenoud valve . Faulty PCB . Oil and moisture contained In the compressed air | . Disassemboe and clean . Replace .Replace .check above issues .Replace .Replace .Replace .Install an air dehydrator |